Customization: | Available |
---|---|
Nature of Source Flow: | DC to AC Inverter |
Phase: | Single |
Still deciding? Get samples of US$ 380/Set
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
BDM 800
|
Input DC
|
|
Recommended Max PV Power (Wp)
|
1200
|
Recommended Max DC Open Circuit Voltage (Vdc)
|
60
|
Max DC Input Current (Adc)
|
17×2
|
MPPT Tracking Accuracy
|
>99.5%
|
MPPT Tracking Range (Vdc)
|
22-55
|
Isc PV (absolute maximum) (Adc)
|
20 x 2
|
Maximum Inverter Backfeed Current to the Array(Adc) | 0 |
Output AC
|
|
Rated AC Output Power (Wp)
|
800
|
Nominal Power Grid Voltage (Vac)
|
768 / 700 / 750
|
Allowable Power Grid Voltage (Vac)
|
211V-264* / 183V-228* / configurable*
|
Allowable Power Grid Frequency (Hz)
|
59.3 a 60.5* / configurable
|
THD
|
<3% (at rated power)
|
Power Factor (cos phi, fixed)
|
-0.99>0.9 (adjustable) / 0.8un>0.8ov
|
Rated Output Current (Aac)
|
3.2 / 3.36 / 3.26
|
Current (inrush)(Peak and Duration)
|
9.4A, 15us
|
Nominal Frequency (Hz)
|
60 / 50
|
Maximum Output Fault Current (Aac)
|
9.6A peak
|
Maximum Output Overcurrent Protection (Aac)
|
10
|
Maximum Number of Units Per Branch (20A) (All NEC adjustment factors have been considered) |
5 / 5 / 5
|
System Efficiency
|
|
Weighted Averaged Efficiency (CEC)
|
95.50%
|
Night Time Tare Loss (Wp)
|
0.11
|
Protection Functions
|
|
Over/Under Voltage Protection
|
Yes
|
Over/Under Frequency Protection
|
Yes
|
Anti-Islanding Protection
|
Yes
|
Over Current Protection
|
Yes
|
Reverse DC Polarity Protection
|
Yes
|
Overload Protection
|
Yes
|
Protection Degree
|
NEMA-6 / IP-66 / IP-67
|
Ambient Temperature
|
-40°F to +149°F (-40°C to +65°C)
|
Operating Temperature
|
-40°F to +185°F (-40°C to +85°C)
|
Display
|
LED LIGHT
|
Communications
|
Power Line
|
Dimension (W-H-D)
|
8.8" x 8.2" x 1.38" (268x250x42 mm)
|
Weight
|
6.4 lbs. (2.9 kg)
|
Environment Category
|
Indoor and outdoor
|
Wet Location
|
Suitable
|
Pollution Degree
|
PD 3
|
Overvoltage Category
|
II(PV), III (AC MAINS)
|
Product Safety Compliance
|
IEC/EN 62109-1, IEC/EN 62109-2
Other Certificates are Optional
|
Grid Code Compliance* (Refer to the lable for the detailed grid code comliance) |
IEEE 1547,VDE-AR-N 4105*,VDE V 0126-1-1/A1 AS 4777.2 & AS,TOR Erzeuger Typ A |